43 replacement parts electrical schematics, Threephase schematic,301-ht – Moyer Diebel 301HT User Manual

Page 51

Advertising
background image

43

REPLACEMENT PARTS

ELECTRICAL SCHEMATICS

DRIP PAUSE

DM2

DM3

DM4

120 SEC WASH

RINSE

DM1

0

SELF FEEDING

150 SEC

* TIMER MOTOR OFF = DELAY FOR BOOSTER HEATING

*

TIMER SEQUENCE DIAGRAM

BTS

DSS

HLTS

PS

PSW

2

1

3

15

HLTS

WTS

TH

13

11

4

12

7

7

18

16

PL

3

4

1CR

CL

6

M1

M3

M2

M4

8

8

6

6

10

10

1CR

PB

DRP

5

RV

STMD

9

9

9

20

6

5

21

21

1

1

1

1

4

11

42
41

40

DOOR CONTACT

BOOSTER THERMOSTAT

BOOSTER HEATER ELEMENT

CAPACITOR

TANK HEATER ELEMENT

M1/4

BOOSTER CONTACTOR

START MANUAL DRAIN

CD

BC1

STMD

DISCHARGE PUMP

AUXILLIARY RELAY

CYCLE START BUTTON

TIMER CONTACTS

1CR

DRP

PB

HOT WATER SOLENOID VALVE

TIMER MOTOR

WASH PUMP MOTOR

TR

MTR

RV

TH

BOOSTER SAFETY THERMOSTAT

BTS

BH

HLTS

DSS

CYCLE LIGHT

POWER ON LIGHT

SYMBOL

ON/OFF BUTTON

PRESSURE SWITCH

CL

PL

PSW

PS

DESCRIPTION

DP

WTS

TANK THERMOSTAT

HTLS

TANK HIGH LIMIT THERMOSTAT

DP

DETERGENT PUMP

1

CD

11

5

8

11

15

3

21

5

6

6

6

6

9

21

16

7

5

1

1

1

1

1

1

1

1

1

2

3

DELTA CONNECTION

FOR 3 PHASE

BH

1

13

BY

DATE

DESCRIPTION

REV.

B

REV.

SCALE

DR.BY

DATE

SHEET

REV.

DESCRIPTION

DATE

BY

THREEPHASE

SCHEMATIC,301-HT

0510727

0

SCALE

JMCALLISTER

22SEP03

SH1

OF

1

L1

L2

HC1

1CR

HC1

TR

MTR

6/9KW BOOSTER HEAT

L3

CUSTOMER TO SUPPLY RATED VOLTAGE/PHASE/Hz, AS SPECIFIED PER ORDER,TO DISCONNECT SWITCH. ALL POWER SUPPLIED TO EACH CONNECTION POINT MUST COMPLY WITH ALL LOCAL ELECTRIC CODES.

GND

230V/3 ~ 60HZ

5 SEC

5 SEC

5 SEC

2 SEC

15 SEC

3 SEC

10 SEC

Advertising