Micro Technic Micronix PV-5127 User Manual

Page 10

Advertising
background image

Users Manual & Installation Guide

PV- 5127:

Power supply module with UPS

Page 10 of 31

ATX connector (CN10)
The ATX connector holds the three ATX-signals: PS_ON, PWR_GOOD and +5V Standby.

The layout of this connector is shown in the schematic. The function of the individual ATX signals

is shown in the table:

ATX signal

Pin no

Function

GND

1

System GND

*

2

For factory use only

*

3

For factory use only

*

4

For factory use only

*

5

For factory use only

*

6

For factory use only

+5V STB

7

+5V Standby

PWR_GOOD

8

This pin is 3.3V when +5V and +12V is OK

PS_ON

9

This pin must be pulled low in order to start PV-5127

GND

10

System GND

Ext. sensor connector (J2)
This connector is for an external ambient (system) temperature sensor, see section System

temperature. The input is designed for the Infineon KTY11-5 temperature dependent resistor

(Infineon ordering code Q62705-K245). Mating connector for J2 is Molex 7880-2. A ready-made

sensor with a 40 cm cable and connector is available as the PV-5127-TW40 accessory.

Batt. sensor connector (J1)
This connector is for an external battery temperature sensor, or a jumper, see section Battery

monitor and charger. The input is designed for the Infineon KTY11-5 temperature dependent

resistor (Infineon ordering code Q62705-K245). Mating connector for J1 is Molex 7880-2. A

ready-made sensor with a 40 cm cable and connector is available as the PV-5127-TW40 accessory.

From the factory, a jumper is installed, disabling the battery temperature control.

Pinheader (ST3)
This pinheader is for configuring the System temperature measurement, see section System

temperature. You can mount a jumper in the “10°C” position, in the “On-board sensor” position, or

you can leave it unconnected. The factory default is a jumper in the “10°C” position.

Jumper position (ST3)

Input for System temperature

No jumper installed

Sensor connected to J2

Jumper on ‘On-board sensor’

On-board sensor. Leave J2 unconnected.

Jumper on ‘10°C’

Simulate +10°C. Leave J2 unconnected. (Factory default)

Advertising
This manual is related to the following products: