Micron Technology Turbofan User Manual

Page 22

Advertising
background image

DRAFT

21

SPEED

km/hr

4

6

8

10

15

20

25

30

4

0.03

0.04

0.05

0.07

0.10

0.13

0.17

0.20

6

0.04

0.06

0.08

0.10

0.15

0.20

0.25

0.30

8

0.05

0.08

0.11

0.13

0.20

0.27

0.33

0.40

10

0.07

0.10

0.13

0.17

0.25

0.33

0.42

0.50

12

0.08

0.12

0.16

0.20

0.30

0.40

0.50

0.60

14

0.09

0.14

0.19

0.23

0.35

0.47

0.58

0.70

SWATH WIDTH (metres)

This is converted to hectares by dividing by 10,000:

Area treated

=

1000 x S x W =

S x W ha/minute

60 x 10,000

600


This gives the standard formula for calculating the coverage of a sprayer:

Area/min =

swath width (m) x speed (km/hr)

ha/min

600


Example:

Speed

: 8km/hour

Swath

width:

12

m


Therefore:

Area treated

=

S x W

=

8 x 12

=

0.16 ha/min

600 600

Table 2 shows the coverage of the sprayer for various swath widths and spraying
speeds.

4. Calculate the required output from the sprayer in litres/minute to give the correct

application rate for the chemical being used.

The output rate of chemical is given by the area sprayed (in hectares) per minute
multiplied by the required application rate in litres per hectare.

Example:

Coverage:

0.16

ha/min

Application rate:

100 l/ha

Output =

0.16 x 100

=

16 l/min

Table 2 – Coverage of sprayer in ha/min

Advertising