4

3.0 TEN KEY POINTS FOR USERS

The following list of ten points is intended to assist users in the efficient use of Turbofan
sprayheads. It is hoped that this section will encourage users to read the entire handbook
and follow its recommendations.

1. Check that all atomisers rotate freely. The only friction should be drag from the hy-

draulic motor. If binding or roughness is felt, remove the unit as described in Section
8.2 (‘Maintenance, Dismantling of Sprayhead and Atomiser’ ) and inspect the bear-
ing, motor, etc.

2. Check that each atomiser securing screw (Page 25, Item no 7, Micron part no 5983) is

secure.

3. Check that the atomiser discs are free of damage, blockage by dried chemical or any

condition which could cause them to run out of balance.

4. Check that the fan blades are not damaged or out of balance.

5. Ensure that the hydraulic system is filled with oil, is correctly adjusted and that all

atomisers are rotating at the correct speed.

6. Check that the correct flow restrictor orifices are fitted.

7. Ensure that all atomisers are correctly positioned on the boom or support structure

and that they are the correct distance from the target being sprayed.

8. Inspect the entire sprayer for damaged or twisted hoses and ensure that there are no

leaks in the hydraulic or chemical systems.

9. Whilst spraying, verify the accuracy of the calibration of the sprayer by checking the

volume of chemical used against the area sprayed.

10. After use, always flush out the entire system with clean water or a suitable solvent.

Never leave chemical residues in the sprayheads, tank or pipework. Wash off the
outer surfaces of sprayheads, booms, etc with a pressure washer or similar to avoid
build up of pesticide residues.