NPort 5600 Series User’s Manual

Initial IP Address Configuration

2-6

To set a termination resistor to 150 KΩ, make sure both of the assigned DIP switches are in the
OFF position. This is the default setting.

To set a termination resistor to 1 KΩ, make sure both of the assigned DIP switches are in the ON
position.

ATTENTION

Do not use the 1 K

Ω setting on the NPort 5650 when using the RS-232 interface. Doing so will

degrade the RS-232 signals and shorten the maximum allowed communication distance.

NPort 5650 DIP Switches

S1 for Port 1
S2 for Port 2
S3 for Port 3
S4 for Port 4
S5 for Port 5
S6 for Port 6
S7 for Port 7
S8 for Port 8
S9 for Port 9
S10 for Port 10
S11 for Port 11
S12 for Port 12
S13 for Port 13
S14 for Port 14
S15 for Port 15
S16 for Port 16