NPort 5600 Series User’s Manual

Configuring NPort Administrator

5-11

Operating Settings

Click Operating Settings located under Main Menu, to display the operating settings for all of
NPort’s serial ports.

Real COM Mode

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

7 min

Optional

0 min: TCP connection is not closed due to an idle TCP connection.

1 to 99 min: NPort automatically closes TCP connection if there is no TCP activity for the given
time. After the connection is closed, NPort starts listening for another Real COM driver
connection from another host.