To Reset the Counter of the Drum Cartridge

Perform the following procedure to reset the drum cartridge counter
after you replace the drum cartridge.

1

While holding down the panel button, turn on the printer.

2

Keep the panel button held down, and the Ready indicator will
start to blink. After the Ready indicator has blinked for about 5
seconds, release the panel button. This should cause all the
indicators to start to blink.

3

After confirming that all the indicators are blinking, briefly press
the panel button. This causes the Error indicator to blink and
all the other indicators to turn off.

4

After a few seconds, all the indicators start to blink again, indi-
cating that the drum cartridge counter has been reset.

5

Turn off the printer. The printer will be ready to print the next
time you turn it on.