4 AT Commands, S-Registers, and Result Codes

40

MultiModemII User Guide

Command:

&V1

Display Last Connection Statistics

Values:

1

Default:

None

Description:

Displays statistics for the last connection. Not available in all
versions.

Command:

&W

n Store Current Configuration

Values:

n = 0 or 1

Default:

None

Description:

&W0 Stores current modem settings in nonvolatile memory as Profile 0.

Profile 0 is loaded instead of the factory defaults at power-on
(if &Y0 is set) and by the ATZ command.

&W1 Stores current modem settings in nonvolatile memory as Profile 1.

Profile 1 is loaded instead of the factory defaults at power-on
(if &Y1 is set) and by the ATZ1 command.

Note:

See also the Z, &F, and &Y commands.

Command:

&X

n

Synchronous Clock Source

Values:

n = 0, 1, or 2

Default:

0

Description:

Selects the source of the transmit clock for synchronous mode.
In asynchronous mode, the transmit and receive clocks are
turned off. In synchronous mode, the clocks are turned on with
a frequency of 1200 Hz or faster corresponding to the speed
that is selected for modem operation.

&X0

Selects internal timing. The modem generates the transmit
clock signal and applies it to the TXCLK output at the serial
interface.

&X1

Selects external timing. The local DTE sources the transmit clock
signal on the XTCLK input of the serial interface. The modem
applies this clock to the TXCLK output at the serial interface

&X2

Selects slave receive timing. The modem derives the transmit
clock signal from the incoming carrier and applies it to the
TXCLK output at the serial interface

Command:

&Y

n

Select Profile for Hard Reset

Values:

n = 0 or 1

Default:

None

Description:

&Y0

Select profile 0 to be loaded on power-up.

&Y1

Select profile 1 to be loaded on power-up.

Note:

See also the &W and Z commands.

Command: &Zy=x Store Telephone Number
Values:

y = 0–3
x = Dialing command

Default:

None

Description:

Stores telephone dial string x in memory location y. Each tele-
phone number dial string can contain up to 30 digits. Dial the
stored number using the DS=y command.

Note:

DTR dialing uses the number stored in memory location 0.