4 at commands, s-registers, and result codes, Multimodemii user guide – Multitech MULTI MODEM II MT5600BA User Manual

Page 52

Advertising
background image

4 AT Commands, S-Registers, and Result Codes

46

MultiModemII User Guide

Command:

**

n

Flash Memory Download

Values:

n = 0, 1, or 2

Description:

**0

Initiate download to flash memory at the last sensed speed.

**1

Initiate download to flash memory at 38.4K bps.

**2

Initiate download to flash memory at 57.6K bps.

Command:

*B

View Numbers in Blacklist

Values:

n/a

Description:

If blacklisting is in effect, AT*B displays a list of numbers for
which the last call attempted in the previous two hours failed.
Permanently forbidden numbers as defined by country re-
quirements do not appear in this list. If no numbers are black-
listed, only the OK result code is displayed.

Command:

*D

View Delayed Numbers

Values:

n/a

Description:

AT*D

displays a list of delayed numbers, as defined in the *B

command, together with their delay times. If no numbers are
delayed, only the OK result code is displayed.

Command: #CBNy=[-]x Store Callback Number
Values:

y = 01–30
x = dialing string

Default:

None

Description:

Stores the callback dialing string x in memory location y. The
dialing string can include the digits 0 through 9 and any of the
following characters: #, *, comma (,), semicolon (;), W, A, B, C,
and D. Up to 30 characters can be used. Example:
AT#CBN01=9,16127853000

. If the optional - character precedes

the dialing string, and the caller appends the same character to
the password, the caller is immediately connected, and the
hangup and callback are skipped.

Command: #CBPy=x Store Callback Password
Values:

y = 01–30
x = password (6–10 characters)

Default:

None

Description:

Stores callback security password x in memory location y. The
password must have 6 to 10 characters. Example:
AT#CBP01=gilgamesh

.

Note:

A direct connect password may not end with a hyphen (-).

Advertising