Warning, Important, General – Marley Engineered Products Radiant Plug-in Heaters FRR10512B User Manual

Page 2: Installation of quartz tube elements, Chain mounting (indoor only)

Advertising
background image

General

These heaters are designed for indoor chain mounting. Not for
recess installation. Elements may be installed prior to mounting
unit. DO NOT USE IN OUTDOOR LOCATIONS

Mounting Limitation– Observe all minimum dimensions from
ceiling, walls, floor and combustible material.

Maintain minimum clearances of:

– 12" (305 mm) to vertical wall surface parallel to heater

– 6" (152 mm) from ends of heater to vertical wall surfaces

– 6" (152 mm) to ceiling

– 72" (1829 mm) to floorWhen heater is mounted the minimum
distance to the wall, do not angle the heater toward the wall.

Installation of Quartz

Tube Elements

1.

Remove two end caps (4 screws) and wire guard to gain
access to terminal blocks.

2.

Remove element from wrapping.

NOTE: Do not handle quartz element with bare hands, or with
gloves or rags that may have grease on them.
3.

Feed the element wire through element support bracket,
install fiberglass sleeving, and plug female quick connect
from element to male quick connect from terminal block.

4.

Replace end caps and wire guard.

Chain Mounting (Indoor Only)

1.. Attach chain links to ceiling accordingly, to achieve desired

mounting height (see Mounting Limitation).

2.

Attach “S” hook to top of heater enclosure to complete
mounting.

3.

Plug heater power supply cord into 120 volt 3 wire outlet. The
power cord is equipped with a 3 wire grounded plug and must
be inserted into a matching receptacle. (see warnings
1,2,3,&4)

Figure 2

Excess element lead wires could come in contact with the
heater enclosure and create an electrical shock or fire hazard.
Leads must be covered by fiberglass sleeve.

a

WARNING

!

The UL listing for this ceiling mounted heater requres that it be
positively mounted to the ceiling structure so that it cannot be
removed without the use of a tool. Attach support chains provided
with heater to ceiling structure using bolts or other hardware so
that heater cannot be removed without a tool. If the "S" hooks are
used for mounting, they must be closed to assure the heater is
permanently mounted.

a

IMPORTANT

!

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted against
defects in workmanship and materials for one year from date of installation. This war-
ranty does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to equipment
improperly installed or wired or maintained in violation of the product’s installation
instructions. All claims for warranty work must be accompanied by proof of the date
of installation.

The customer shall be responsible for all costs incurred in the removal or reinstalla-
tion of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations of this war-
ranty, inoperative units should be returned to the nearest Marley authorized service
center or the Marley Engineered Products Service Center, and we will repair or
replace, at our option, at no charge to you with return freight paid by Marley. It is
agreed that such repair or replacement is the exclusive remedy available from
Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED
THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND
EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS
SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH
RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT,
STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion or limitation may not apply to you. This warranty
gives you specific legal rights, and you may also have other rights which vary from
state to state.

For the address of your nearest authorized service center, contact Marley
Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned
to the factory must be accompanied by a return authorization and service identifica-
tion tag, both available from Marley Engineered Products. When requesting return
authorization, include all catalog numbers shown on the products.

Part No. 5200-2437-004

ECR 37239

5/07

Figure 1

470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

ELEMENT

TERMINAL BLOCK

HOW TO OBTAIN WARRANTY SERVICE AND
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

Advertising