Setting the water hardness selector
inside the wash cabinet.

The water hardness selector is factory
set to position 6. It should only be reset
if your water hardness is in the range of
650 - 1170 ppm (mg/l).

ppm

(mg/l)

gr/Impgal

water

hardness

selector

(Position)

20- 630

1.4 - 44.2

6*

650- 850

45.6 - 59.6

4

860-1170

60.4 - 82.1

5

1190-1260

83.5 - 88.4

6*

* = factory setting

Do not set the selector on positions
1 - 3.

Using a screwdriver, remove the
cover from the water hardness selec-
tor.

Using a coin or screwdriver, turn the
selector dial to the desired setting.

Example:
If the water hardness is 670 ppm (mg/l),
set the selector to position 4 (650 - 850
ppm (mg/l)).

Replace the cover on the water hard-
ness selector.