3-1. Specifications

Type of Input

Power

Welding Power

Source Type

Wire Feed Speed

Range

Wire Diameter

Range

Welding Circuit

Rating

Weight

24 Volts AC

Single-Phase

10 Amperes

50/60 Hertz

Constant Voltage (CV)

DC With 14-Pin And

Contactor Control

Standard: 50 To 780 ipm

(1.3 To 19.8 mpm)

Optional High Speed: 92

To 1435 ipm (2.3 To 36.5

mpm)

.023 To 1/8 in (0.6

To 3.2 mm)

Max Spool Weight:

60 lb (27 kg)

100 Volts,

750 Amperes, 100%

Duty Cycle

12 ft (3.7 m):

207 lb (94 kg)

16 ft (4.9 m):

280 lb (127 kg)

12 ft (3.7 m) Boom

16 ft (4.9 m) Boom

Maximum Height With 4 ft (1.2 m) Post

17 ft (5.2 m)

21 ft (6.4 m)

Vertical Lift Of Boom

Horizontal to 60

°

Above Horizontal

Horizontal to 60

°

Above Horizontal

SECTION 4 − INSTALLATION

4-1. Installing Swivel Into Pipe Post

152 268-B

Y Do not remove Safety Collar

until instructed to.

1

Swingpak Base or CBC Cart

2

Pipe Post With Base

3

Steel Bolt

Secure as shown using as a mini-

mum 1/2 in diameter SAE grade 5

steel bolts.
4

Swivel Assembly

Insert into pipe post. Lubricate

swivel.
5

Safety Collar

Tools Needed:

3/4 in

1

2

3

4

5

Advertising