2. diagnostics – Miller Electric and DS-74D16 User Manual

Page 25

Advertising
background image

OM-1500-13 Page 21

6-2. Diagnostics

803 063-A

1

LED3 On Right Side Motor

Control Board PC1

2

LED3 On Left Side Motor

Control Board PC101

3

LED3 On Dual Board PC70

2

1

3

Display On

Optional Meter

LED3 Sequence

Indicated Error

Left Side Motor Control

HELP 11

1 Blink

Communication Error

Left Side Motor Control

Board PC101

HELP 12

2 Blinks

Trigger Error

HELP 13

3 Blinks

Tach Error

HELP 14

*4 Blinks

Motor Error

Right Side Motor Control

HELP 21

1 Blink

Communication Error

Right Side Motor Control

Board PC1

HELP 22

2 Blinks

Trigger Error

HELP 23

3 Blinks

Tach Error

HELP 24

*4 Blinks

Motor Error

Dual Board PC70

HELP 31

*4 Blinks

Communication Error

*Since blink On time and blink Off time are equal in a four-blink

cycle, the four−blink sequence appears as constant blinking.

Error Indications

Error conditions are indicated by LED3 on

PC1, PC101, PC70 or on display if meter op-

tion is present. To view LED3, turn Off unit, re-

move wrapper, and turn unit On. LED3 is most

easily observed from the left side of the unit.
The LED blinks in a 2.5 second cycle. The

number of blinks in this period indicates the

type of error.
The priority of the errors is related to the num-

ber of blinks indicating the error. The more

blinks, the more severe the error (motor error

is top priority). A higher priority error overrides

a lower one (if a motor error and a communica-

tion error existed, the light would blink four

times for the motor error).

The communication error occurs 2.5 sec-

onds after a loss of communication between

the motor and the optional meter board or

Dual board. The user may continue to weld

with this error. The error may be cleared by

turning power Off, waiting a minimum of two

seconds, and turning power On.

The trigger error occurs if the user has the

trigger held for more than two minutes with-

out striking an arc (providing current over-

ride is not enabled), or if the user holds the

trigger past the postflow phase in a timed

weld. This error also occurs if the trigger is

held when the feeder is powered up. The er-

ror may be cleared by releasing the trigger.

The tach error occurs 2 seconds after the

loss of tachometer feedback. The user may

continue to weld with this error. The motor

speed is regulated through the monitoring of

voltage and current.

The motor error indicates that the motor

has been drawing too much current for too

long.