OM-210 540 Page 34

SECTION 7 − TROUBLESHOOTING

7-1.

Set Value Mode

Program

Process

Wire Type

Gas Type

Adjust

Volts

Arc Adjust

Wire Speed

Amps

Setup

Arc Control

Wirefeed

Gas

Contactor

The Set Value mode is a troubleshooting tool
that allows certain robot command values to
be manually over-ridden.

1

Setup Push Button

2

Arc Control Push Button

3

Adjust Knob

4

Wire Feed Speed/Amps Display Push
Button

Enter the Set Value mode by pressing the
Setup and Arc Control push buttons at the
same time. When in the Set Value mode the
display windows briefly shows SET VALU and
the blinking LED’s under the display windows
indicate whether Volts, Arc Adjust, or Wire
Speed can be changed turning the Adjust
knob.
Depending on the defined weld process,
either volts (MIG) or arc adjust [pulse,
Accu-pulse, or RMD (optional)] can be
changed in the top display. Wire speed can be

changed in the bottom display. Press the Wire
Feed Speed/Amps push button to toggle
between selecting information in the top
display or bottom display. The LED under the
active display will blink to indicate the value
that can be changed.

Rotate the Adjust knob to change values.

Exit the Set Value mode by pressing the Setup
and Arc Control push buttons at the same time
or turning power source off and then back on
again.