OM-210 540 Page 44

LED

Diagnosis

Status

24

On

Input signal On from relay K4 to indicated wire stuck in weld joint

Off

Input signal Off from relay K4 to indicate wire is not stuck in weld joint

25

On

Indicates +5 volts dc is present on automation module PC9

Off

Indicates +5 volts dc is not present on automation module PC9

26

On

Input signal on from relay K5 for flow (shielding gas or coolant) present

Off

Input signal off from relay K5 for flow (shielding gas or coolant) not present

27

On

Indicates −15 volts dc is present on automation interface module PC9

Off

Indicates −15 volts dc is not present on automation interface module PC9

28

On

Indicates +15 volts dc is present on automation interface module PC9

Off

Indicates +15 volts dc is not present on automation interface module PC9

29

On

Input signal on from relay K6 for arc detected

Off

Input signal off from relay K6 for no arc detected

30, 31

On

See Network Status Table in Section 7-12

Off

See Network Status Table in Section 7-12

32

On

Input signal on for aux. relay energized

Off

Input signal off for aux. relay energized

33

On

Input signal on touch sensor touch detected

Off

Input signal off touch sensor touch not detected