7-11. Diagnostic LED’s On Automation Interface Module PC9

LED

Status

Diagnosis

1

On

Input signal On from robot for jog advance

Off

Input signal Off from robot for no jog advance

2

On

Input signal On from robot to energize contactor

Off

Input signal Off from robot to not energize contactor

3

On

Input signal On remote program A selected

Off

Input signal Off remote program A not selected

4

On

Input signal On remote program C selected

Off

Input signal Off remote program C not selected

5

On

Input signal On from E-stop board PC12 for no emergency stop

Off

Input signal Off from E-stop board PC12 acknowledges E-stop is On from robot

6

On

Spare 1 not assigned

Off

Spare 1 not assigned

7

On

Input signal On Autoset-C selected

Off

Input signal Off Autoset-C not selected

8

On

Input signal On Autoset-B selected

Off

Input signal Off Autoset-B not selected

9

On

Input signal On Remote Jog on from peripheral plug

Off

Input signal Off Remote Jog off from peripheral plug

10

On

Input signal On Remote Purge on from peripheral plug

Off

Input signal Off Remote Purge off from peripheral plug

11

On

Input signal On from robot for jog retract

Off

Input signal Off from robot for no jog retract

12

On

Input signal On from robot for purge

Off

Input signal Off from robot for no purge

13

On

Input signal On remote program B selected

Off

Input signal Off remote program B not selected

14

On

Input signal On Touch Sensor on from robot or peripheral plug

Off

Input signal Off Touch Sensor off from robot or peripheral plug

15

On

Spare 0 not assigned

Off

Spare 0 not assigned

16

On

Spare 2 not assigned

Off

Spare 2 not assigned

17

On

Input signal On Autoset-A selected

Off

Input signal Off Autoset-A not selected

18

On

Input signal On Autoset-D selected

Off

Input signal Off Autoset-D not selected

19

On

Input signal On Remote Retract on from peripheral plug

Off

Input signal Off Remote Retract off from peripheral plug

20

On

Input signal On Remote Water Flow on from peripheral plug

Off

Input signal Off Remote Water Flow off from peripheral plug

21

On

Input signal On from robot for no emergency stop

Off

Input signal Off from robot for emergency stop

23

On

Input signal On from relay K3 for welding power source ready and no detected errors present

Off

Input signal Off from relay K3 for welding power source not ready, detected errors are present, or unit is
in operating mode preventing the weld ready signal from being enabled