Bench testing, Before you begin – Motorola BLE*/* User Manual

Page 36

Advertising
background image

BLE*/* Installation and Operation Manual

Section 4

Bench Testing

Motorola’s recommended procedure for placing a new BLE*/* into service is to fully test it on the
bench before it is field installed. There are specific alignment procedures that ensure proper
functioning of all components and simplify final installation. If the BLE*/* is properly aligned
on the bench only minor adjustments may be required in the field.

The following subsections provide instructions to bench align the BLE*/*.

Before You Begin

The BLE*/* is shipped with a 20 ampere blade-type fuse in the output port for over current
protection.

CAUTION!

To avoid applying 60/90 Vac to the test equipment during testing, remove the fuse illustrated in Figure 2-8.

Open the housing and remove the chassis cover. Refer to your system drawings or records to
confirm the presence of the required options as described in Section 2, “Overview,” Options and
Accessories.

Advertising