Table 19: Turn On/Off Timing

Item

Description

MIN

MAX

UNITS

T

sb_on_delay

Delay from AC being applied to 5 VSB being
within regulation.

1500

ms

T

ac_on_delay

Delay from AC being applied to all output voltages
being within regulation.

2500

ms

T

vout_holdup

Time all output voltages stay within regulation
after loss of AC.

18

ms

T

pwok_holdup

Delay from loss of AC to deassertion of PWOK.

17

ms

T

pson_on_delay

Delay from PSON

#

active to output voltages within

regulation limits.

5

400

ms

T

pson_pwok

Delay from PSON

#

deactive to PWOK being

deasserted.

50

ms

T

pwok_on

Delay from output voltages within regulation limits
to PWOK asserted at turn on.

200

1000

ms

T

pwok_off

Delay from PWOK deasserted to output voltages
(3.3 V, 5 V, 12 V, -12 V) dropping out of regulation
limits.

1

ms

T

pwok_low

Duration of PWOK being in the deasserted state
during an off/on cycle using AC or the PSON#
signal.

100

ms

T

sb_vout

Delay from 5 VSB being in regulation to O/Ps
being in regulation at AC turn o n.

50

1000

ms

STATUS

Recommended

Item

Description

MIN

MAX

UNITS

T

vout_holdup

Time all output voltages stay within regulation
after loss of AC.

21

ms

T

pwok_holdup

Delay from loss of AC to deassertion of PWOK.

20

ms

T

sb_holdup

Time 5VSB output voltage stays within regulation
after loss of AC.

70

ms