Intel Entry Redundant Power 2U ERP2U User Manual

Page 29

Advertising
background image

SSI

ERP2U Power Supply Design Guide, V1.0

- 29 -

Asset Tag

{Not used, code is zero length byte}

FRU File ID

{Not required}

PAD Bytes

{Added as necessary to allow for 8 -byte offset to next area}

8.3.3.2 MultiRecord Area

As defined by the IPMI FRU document. The following record types shall be used on this power supply:

Power Supply Information (Record Type 0x00)

DC Output (Record Type 0x01)

No other record types are required for the power supply.

MultiRecord information shall be defined as follows:

Table 27: FRU Device Product Information Area

Field Name (PS Info)

Field Information Definition

Overall Capacity (watts)

480

Peak VA

550

Inrush current (A)

50

Inrush interval (ms)

5

Low end input voltage range 1

90

High end input voltage range 1 140

Low end input voltage range 2

180

High end input voltage range 2 264

A/C dropout tol. (ms)

20

Binary flags

Set for: Hot Swap support, Autoswitch, and PFC

Peak Wattage

Set for: 10 s, 550 W

Combined wattage

Set for 5 V & 3.3V combined wattage of 115 W

Predictive fail tach support

Not supported, 00h value

Field Name (Output)

Field Description:

Five outputs are to be defined from #1 to #5, as follows: +3.3 V, +5
V, +12 V, -12V, and +5 VSB.

Output Information

Set for: Standby on +5 VSB, No Standby on all others.

All other output fields

Format per IPMI specification, using parameters in the EPS12V
specification.