1 configure the network settings, 1 by “configuration wizard – ICP DAS USA 8KE8 User Manual

Page 25

Advertising
background image

Chapter 2. Configure the 8430/8830/8KE4/8KE8 and I/O
modules

Before using the 8430/8830/8KE4/8KE8 and any I/O modules connected to it, the following
settings must be configured:

Networking settings: IP, Mask, Gateway of 8430/8830/8KE4/8KE8

Power on value of AO, DO modules

Safe value of AO, DO modules

Input range of AI modules

Noise filter of AI modules

Check sum of all communication protocol

The most important thing at the beginning stage is the network setting. After assigning the
network setting, the VxComm Utility can be used to create a virtual COM port to map the
8430/8830/8KE4/8KE8, and then the DCON utility can be used to configure other settings.

2.1 Configure the network settings

Network settings can only be configured via the RS-232 COM Port.
There are three tools that can be used to configure the network settings of
8430/8830/8KE4/8KE8.

By “Configuration Wizard

By “MiniOS7 Utility

By “SMMI Menu

2.1.1 By “Configuration Wizard”

The “Configuration Wizard” gives step by step information for configuring the network
settings. The wizard is most useful for detecting the host PCs network settings, searching
the local network to locate a valid IP, Mask and Gateway address. Using the “Configuration
Wizard”, allows automatic detection of the important settings, removing the need to contact
system administrators for support.

Step1: Use CA-0915 to connect COM1 of 8430/8830/8KE4/8KE8 to COM1/2 of the host

PC.

Step2: Install PCDiag to the host PC by running

CD:\Napdos\7188e\tcp\PCDiag

Step3: Follow the instructions given by the “Configuration Wizard” until the following
window appears

8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 ----- 25

Advertising
This manual is related to the following products: