Gas connection, Conversion from lpg to natural gas – IDEAL INDUSTRIES IZGS 68 ICTX User Manual

Page 13

Advertising
background image

13

Gas Connection

Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.

steel or copper.

The connection should be suitable for
connecting to RC 1/2 (1/2 BSP male

thread).
Important
When the final connection has been

made, it is essential that a thorough leak

test is carried out on the hob and
installation. Use some soapy water,
never a flame.
Ensure that the main connection pipe

does not exert any strain on the hob.

It is important to install the elbow
correctly, with the shoulder on

the end of the thread, fitted to the

hob connecting pipe.
Failure to ensure the correct

assembly will cause leakage of

gas.

A) End of shaft with nut
B) Washer
C) Elbow

Conversion from LPG to Natural Gas

IMPORTANT
The replacement/conversion of the gas

hob should only be undertaken by a
competent person.

It is important to note that this model is
designed for use with LPG gas but can
be converted for use with Natural gas
providing the correct injectors are fitted
and the gas rate is adjusted to suit.
Replace the rating label (placed near the
gas supply pipe) with the relevant one
for the new type of gas supply. You can
find this label in the package of the
injectors supplied with the appliance.

Advertising