7

Operation

Hob burner control knobs

The symbols on the knobs mean:

= no gas supply

= maximum gas supply

= minimum gas supply

For easier lighting, proceed before
putting a pan on the pan support.

Lighting the burners

To light a burner, turn the relevant

knob anticlockwise to maximum
position (

) and push down the knob

to ignite.

After lighting the flame, keep the

knob pushed down for about 5
seconds
. This will allow the
"thermocouple" to be heated and the
safety device to be switched off,
otherwise the gas supply would be
interrupted. Then, check the flame is
regular and adjust it as required.

If you cannot light the flame even

after several attempts, check the "cap"
and “crown” are in the correct position.

In the absence of electricity, ignition

can occur without the electrical device;
in this case approach the burner with a
flame, push the relevant knob down and
turn it anti-clockwise until it reaches the
"maximum" position.

Do not keep the control knob
pressed for more than 15
seconds. If the burner does not
light even after 15 seconds,
release the control knob, turn
it the "off" position and wait for
at least one minute before
trying to light the burner again.
If the burner accidentally goes
out, turn the control knob to

A - Burner cap

B - Burner crown
C - Ignition candle
D - Thermocouple

Triple crown

the "off" position and wait for
at least 1 minute before trying
to light the burner again.

To switch off burners

To put the flame out, turn the knob to

the symbol ().

Take care when frying food in
hot oil or fat, as the overheated
splashes could easily ignite.
When switching on the mains, after
installation or a power cut, it is quite
normal for the spark generator to be
activated automatically.