SSI

EPS1U Power Supply Design Guide, V1.1

8.3 ACWarning

STATUS

Optional

This is an output signal from the power supply which provides a warning to the system that the power supply has
lost its AC input. This signal also provides a signal to synchronize the turn on of multiple power supplies. At turn
on, this signal is pulled LOW when the supply’s internal bulk voltage has reached a level that allows it to turn on.
At turn off ACWarning goes HIGH when the internal bulk voltage drops low enough. The characteristics of the
ACWarning signal is shown in Table 22: ACWarning Signal Characteristics. Refer to Figure 5 for timing diagram.

Table 22: ACWarning Signal Characteristics

Signal Type

Open collector/drain output from power supply. Pull-
up to VSB located in system.

ACWarning = Low

Input voltage within operating range and power
supply is ready to turn on.

ACWarning = High

Input voltage is less than the operating range and the
power supply is turning off.

MIN

MAX

Logic level low voltage, Isink=4mA

0V

0.4V

Logic level high voltage, Isink=50

µA

5.25V

Sink current, ACWarning = low

4mA

Sink current, ACWarning = high

50

µ

A

ACWarning Delay: T

acwarning_delay

8msec

ACWarning rise and fall time

100

µ

sec

Power supply turn on voltage

75VAC

85VAC

Advertising