IBM 8306 User Manual

Page 111

Advertising
background image

Diagnostic

Error

Code

FRU/Action

175-199-XXX

Thermal

Sensor(s)

test

failed,

cause

unknown

1.

Go

to

the

Undetermined

problems

section

2.

Flash

the

system

and

re-test

3.

Replace

component

under

function

test

175-250-XXX

175-251-XXX

Thermal

Sensor(s)

limit

error

1.

Check

fans

2.

Check

Power

supply

3.

Microprocessor

4.

System

board

185-000-XXX

Asset

Security

Test

Passed

1.

No

action

185-XXX-XXX

Asset

Security

failure

1.

Flash

system

2.

System

board

185-278-XXX

Asset

Security

Chassis

Intrusion

1.

Assure

Asset

Security

Enabled

2.

C2

Cover

Switch

3.

System

board

201-000-XXX

System

Memory

Test

Passed

1.

No

action

201-XXX-XXX

System

Memory

error

1.

Replace

the

memory

module

called

out

by

the

test

2.

System

board

202-000-XXX

System

Cache

Test

Passed

1.

No

action

202-XXX-XXX

System

Cache

error

1.

Cache,

if

removable

2.

System

board

3.

Microprocessor

206-000-XXX

Diskette

Drive

Test

Passed

1.

No

action

206-XXX-XXX

Diskette

Drive

error

1.

Diskette

Drive

Cable

2.

Check

power

supply

voltages

3.

Diskette

drive

4.

System

board

215-000-XXX

CD-ROM

Drive

Test

Passed

1.

No

action

215-XXX-XXX

CD-ROM

Drive

error

1.

CD-ROM

Drive

Cable

2.

Check

power

supply

voltages

3.

CD-ROM

drive

4.

System

board

217-000-XXX

Hard

Disk

Drive

Test

Passed

1.

No

action

217-25X-XXX

217-26X-XXX

Hard

Disk

Drive

(IDE)

error

1.

Hard

Disk

Drive

Cable

2.

Check

power

supply

voltages

3.

Hard

Disk

drive

(IDE)

4.

System

board

Chapter

7.

Symptom-to-FRU

Index

105

Advertising