Low surface temperature, Lst standard, Data & dimensions – IDEAL INDUSTRIES 36 User Manual

Page 26: Options

Advertising
background image

low surface temperature

26

72 Models

Heights 500, 650, 800mm

Lengths 560 - 1960mm

Output 196 - 2767 watts

Types K1, P+ & K2

Safety grilles supplied as standard

Casing supplied with valve/pipework

“knockouts” on side panels

Flexibility of choice

Competitively versatile

LST Standard

Height

Emitter

Length

Output Watts at Δ T50

(mm)

Height

(mm)

K1

P+

K2

(mm)

500

300

560

196

284

348

500

300

760

293

426

522

500

300

960

391

568

696

500

300

1160

489

710

870

500

300

1360

587

852

1044

500

300

1560

685

994

1218

500

300

1760

782

1136

1392

500

300

1960

880

1278

1566

650

450

560

290

386

478

650

450

760

435

580

717

650

450

960

580

773

956

650

450

1160

725

966

1195

650

450

1360

870

1159

1434

650

450

1560

1015

1352

1673

650

450

1760

1160

1546

1912

650

450

1960

1305

1739

2151

800

600

560

365

501

615

800

600

760

548

751

922

800

600

960

730

1002

1230

800

600

1160

913

1252

1537

800

600

1360

1096

1502

1844

800

600

1560

1278

1753

2152

800

600

1760

1461

2003

2459

800

600

1960

1643

2254

2767

Data & Dimensions

ٌ

Options

Remote sensing thermostatic valves

Advertising
This manual is related to the following products: