TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (14) cap screw.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (14) cap screw.

Motor blows air or stalls.

Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.

y

y

y

y

y

y

y

Low output volume, erratic fl ow or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation - suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper fl ow if high viscosity fl uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high volume.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

A

B

C

D

N

G

H

J

M

L

F

K

Q - Exhaust Port

R - Material Inlet

R - Material Outlet

P - Air Inlet

DIMENSIONS

A - 23-1/8” (587.4 mm)
B - 30” (762.0 mm)
C - 12-1/32” (306.4 mm)
D - 2-3/4” (69.9 mm)

F - 15” (381.0 mm)
G - 32” (812.8 mm)
H - 10-5/32” (258.0 mm)
J - 11-21/32" (296.1 mm)

K - 9/16” (14.3 mm)
L - 2-3/4" (69.9 mm)
M - 22-27/32” (580.2 mm)
N - 16" (406.4 mm)

P - 3/4 - 14 N.P.T.
Q - 1-1/2 - 11-1/2 N.P.S.M.

“R” Inlet / Outlet

PH30F-ASS-SXX-C

3 - 8 N.P.T.F. - 1

PH30F-BSS-SXX-C

Rp 3 (3 - 11 BSP parallel)

Advertising