Wiring the Hydrotherapy Spa

This procedure must be performed by a qualified,
licensed electrician in accrodance with the nation-
al electric code, and with all local, state, and feder-
al electric code. Under no circumstances should
the hydrotherapy spa be wired by someone other
than a qualified electrician.

Before you have the spa wired, make sure it is in the
desired position, and that it can be easily serviced, if
needed.

The spa operates on a 240 volt power source. It must
be wired directly into a grounded circuit with a 45 amp
circuit breaker and a Ground Fault Circuit Interrupter
(GFCI) capable of carrying 45 amps.

No other appli-

ance should be on the same circuit.

A wire connector is provided on the electronics pack
of the spa to connect a minimum No. 6 AWG (13.3
mm

2

) solid copper conductor between the spa and

any metal equipment, electrical enclosure made of
metal, metal water pipes, or conduit within five feet of
the spa.

Three options for wiring the spa are shown at the
right. A wiring diagram is also found on the inside of
the electronics pack for reference.

Option 1

Main Panel

GFCI Circuit

Breaker

Spa

Wire Length

Suggested Wire Size

5 Feet to 25 Feet

25 Feet to 50 Feet

6 AWG

4 AWG

Option 2

Main Panel

GFCI Circuit

Breaker

Spa

Wire Length

Suggested Wire Size

5 Feet to 25 Feet

25 Feet to 50 Feet

50 Feet to 100 Feet

6 AWG

4 AWG

A

B

6 AWG

4 AWG

2 AWG

4 AWG

Disconnect

Wire

(A)

Wire

(B)

Option 3

Main Panel

Circuit

Breaker

Spa

Disconnect

Wire

(A)

Wire

(B)

GFCI

Min. of

5 feet*

Min. of

5 feet*

More than 50 feet not recommended

More than 100 feet not recommended

Wire Length

Suggested Wire Size

5 Feet to 25 Feet

25 Feet to 50 Feet

50 Feet to 100 Feet

6 AWG

4 AWG

A

B

6 AWG

4 AWG

2 AWG

4 AWG

More than 100 feet not recommended

Min. of

5 feet*

*

The hydrotherapy spa must be placed a minimum

of five feet from the Main Panel.

*

The hydrotherapy spa must be placed a minimum

of five feet from the Disconnect.

*

The hydrotherapy spa must be placed a minimum

of five feet from the Disconnect.