IBM AA-RWF3A-TE User Manual

Page 107

Advertising
background image

CAUTION:

Disassembling any part of the fan assembly voids the part warranty and regulatory

certifications. There are no user-serviceable ports inside the Power Supply/Fan

Assembly Unit.
Because the cooling system relies on pressurized air, do not leave any of the fan

assembly slots empty longer than two minutes while the switch is operating. If a fan

assembly fails, leave it installed in the switch until it can be replaced.
Maintain the two Power Supply/Fan assemblies in operating condition to provide

redundancy.

Table 21

lists power supply/fan assembly unit status LED descriptions, and required

actions.

Table 21 4/32B SAN Switch power supply/fan assembly unit status LED

LED name

LED color and

behavior

Description

Action required

No light

Power supply is not receiving

power or power is off.

Verify that the power supply is on

and seated and the power cord is

connected to a functioning power

source.

Power Supply

Status

Steady green

Power supply is operating

normally.

No action required.

No light

System is off, boot is not complete,

or boot failed.

Verify that the system is on and

booting is complete.

Steady green

System is on and power supplies

are functioning properly.

No action required.

Steady Amber

(for more than 5

seconds)

Boot failed and system is faulty.

Perform the following steps:

1.

Connect a serial cable to the

system.

2.

Reboot the system.

3.

Check the failure indicated on

the system console.

4.

Contact HP Technical Support.

System Status

Flashing amber

or green

Attention is required. A number

of variables can cause this status

including a single power supply

Check the management interface

and the error log for details on the

cause of the status. Contact HP

SAN Switch installation guide

107