Controller termination, Cat5e cable used to connect controllers to mza-4.7 – Integra MZA-4.7 User Manual

Page 11

Advertising
background image

11

Controller Termination

The recommended wiring and color scheme is shown in Fig 2.
Use the Standard 568-B color code for the CAT5E termination to the Controller – see Table 1. Although it is possible
to daisy chain controllers we recommend “home runs” of CAT5E cable with a maximum cable length of 200m.

Note:

Some IR receivers have an Amplifier On indicator, their “On” terminal should be connected to the zone’s AMP

ON output not to the controller interface ports “Data” terminal.

CAT5E cable used to

connect controllers

to MZA-4.7

Fig 2

Orange and Green

White/Green

White/Orange

White/Blue

Pin #

Wire Color

Keypad function

1

White/Orange

+12V DC

supply

2

Orange

0V supply

3

White/Green

IR output

4

Blue

nc

5

White/Blue

Data input

6

Green

0V supply

7

White/Brown

nc

8

Brown

nc

Table 1