Rs232 protocol —continued, Data – Integra MZA-4.7 User Manual

Page 17

Advertising
background image

17

RS232 Protocol—Continued

Notes:

■ Commands are used as notifications. If an amplifier is switched ON, it will notify the other devices on the control

bus by sending the Standby command (01). Any amplifiers with the same zone will take the notification as a
command and also switch ON.

■ When a command is sent to an amplifier it will first be transmitted on the control bus and then returned to the PC

(Home automation system). If an error occurs an error will be returned instead of the original command. The PC
(Home automation system) needs to ignore its command when it is returned.

Data

Command

Content

Standby
(01)

00 – Standby OFF
01 – Standby ON
04 – Toggle

Mute
(02)

00 – Mute
01 – Un-mute
02 – Toggle Mute

Source Selection
(03)

00 – S5
01 – S6
02 – S7
03 – S4
04 – S8
05 – S1
06 – S2
07 – S3

Volume
(04)

00 – A0 range

Bass
(05)

F4 – 0C (–12dB - +12dB)

Treble
(06)

F4 – 0C (–12dB - +12dB)

Balance
(07)

EC – 14 (Left –20dB - Right –20dB)

Send all parameters
(09)

XX – value ignored

Amplifier features
(0C)

00 – Loudness disabled
01 – Loudness enabled

Maximum Volume Limit
(0D)

00 – A0 range

Link Zone
(0F)

00 – 31 zone to be linked
FF – for no zone linking

Volume Up
(11)

XX – value ignored

Volume Down
(12)

XX – value ignored

Zone Name
(1C)

Data field contains the ASCII string

Preamplifier Volume Mode
(1D)

00 – A0 range
FF = Independent mode.

Preset Selection
(1E)

All Zone function: Zone byte = FF
00 – Default : exit preset mode
01 – Force “Page Preset”
02 – Select Preset 1
03 – Select Preset 2
04 – Select Preset 3
05 – Select Preset 4
06 – Select Preset 5
07 – Select Preset 6

Volume BCD Format
(26)

0 – 99 in BCD format same as Front Panel display

Advertising