6 Troubleshooting Guide

This section describes potential installation and configuration problems and solutions, including fault
conditions and indicators. More information is found in the Technical Addendum and on our web site.

6.1

Fault Conditions and Indicators

The following fault conditions are displayed on the control panel along with an alarm sound and blinking
LCD back-light.

Table 3. Fault Indicators.

Control Panel Indication

Fault Condition

Solution

HIGH BATT SHUTDOWN

Battery voltage too high

Check for fault with battery charging
system. Manually reset inverter by
turning switch to ‘0’ then to ‘|’ again.

LOW BATT SHUTDOWN

Battery voltage too low

Charge battery. Manually reset
inverter by turning switch to ‘0’ then
to ‘|’ again.

OVERLOAD SHUTDOWN Battery current too high, probable AC

overload

Reduce load on the inverter.

OVERTEMP SHUTDOWN System over-temperature

Improve ventilation and cooling
and/or reduce load on the inverter.

SYSTEM SHUTDOWN

PS_FAULT SHUTDOWN

DC-DC SHUTDOWN

Overload or system hardware fault

Ensure all loads are disconnected.
Try to reset the unit by switching to
0’ and then to ‘|’. If unit still does
not operate, Contact Iris Technology
for service warranty replacement.

The table below provides some troubleshooting tips:

Table 4. Troubleshooting Tips.

Problem and symptoms

Possible Cause

Solution

No output voltage and control
panel reading 20.4 VDC or lower

Low input voltage shutdown

Recharge battery, check
connections and cable

No output voltage, no voltage
indication.

Inverter switched to ‘0
No battery power to inverter
Reverse DC polarity connection -
internal fuse open

Turn Inverter power switch to ‘I’
Check wiring to inverter.

No output voltage and control
panel reading 32.0 VDC or higher

High input voltage shutdown

Make sure that the inverter is
connected to correct battery
voltage, check regulation of
charging system.

Low battery warning on all the
time, voltage indicator below 22.0
VDC

Poor DC wiring, poor battery
condition

Use proper cable and make solid
connections.
Charge battery or use new
battery.

Advertising