2.1.2

Control Panel

The Control Panel provides ‘0/|’(Off/On) control and displays operating information so you can monitor
the status of the Inverter and your batteries.

This panel can be removed and re-attached in different orientations so the display information is directed
at you in the most convenient fashion, for all recommended mounting configurations.

3 Installation

This section contains instructions for installing the QuietPower Inverter. After securing the unit and
making wiring connections, do not turn the unit on.

Proceed to the next section of the manual which provides operating instructions.

3.1

Requirements for Installation

What You Need to Install the QuietPower Inverter

You need the following tools and hardware to properly install the QuietPower Inverter:

· Wrench for DC terminals (½” or 13 mm)

· Wrench for Vibration Isolators (optional use)

· DC cables (supplied as PN 287A106)

3.2

Locating the QuietPower Inverter

The QuietPower Inverter utilizes complex electronic circuits and although design precautions have been
made for protection of these circuits, they can be susceptible to damage from use in extreme
environments. The QuietPower Inverter should only be installed in a location that meets the following
requirements:

· Dry: do not allow water or other fluids to drip or splash on the QuietPower Inverter. Do not mount the

QuietPower Inverter in an area subject to splashing or dripping water or bilge.

· Cool: normal ambient air temperature should be between 0°C (32°F) and 25°C (77°F) - the cooler the

better within this range. Refer to the operating temperature information in the specifications section
of this manual.

· Ventilated: allow at least 5 inches (13 cm) of clearance all around the unit. Ensure that the ventilation

openings on the unit are not obstructed. If mounting in a compartment, ventilate with louvers or cut-
outs.

· Safe: do not install the QuietPower Inverter in the same compartment as batteries or in any

compartment capable of storing flammable liquids such as gasoline. Do not install the QuietPower
Inverter in an engine compartment or other location where ignition protected equipment is required.

· Dust-free: do not install the QuietPower Inverter in a dusty environment where either dust, wood

particles or other filings/shavings are present. These can be pulled into the unit when the cooling fan
is operating.

· Close to AC junction box: avoid the use of extended wire lengths if possible.

· Close to battery/batteries: Avoid excessive cable lengths but do not install the QuietPower Inverter in

the same compartment as batteries. Use the recommended wire lengths and sizes (see section
3.4.4). Also do not mount the QuietPower Inverter where it will be exposed to the gases produced by
the battery. These gases are very corrosive and prolonged exposure will damage the QuietPower
Inverter.

· Protected from battery acid: Never allow battery acid to drip on the QuietPower Inverter or its wiring

when reading specific gravity or filling the battery.