Typical installation 1.ventilation needs, Determine your ventilation needs, Air volume needed – Imperial SHMTM User Manual

Page 3: Total cu ft x 0.3 per hr = total, Installation, Example

Advertising
background image

PAGE 3

STATIC AND STATIC WITH MOTORIZED DAMPERS MODELS

Determine Your

Ventilation Needs

installation

How much fresh air do I need? Good air
quality is based in part on the capacity of
the home’s ventilation system.

Usually, the HRV’s capacity is measured in
CFM (Cubic Feet per Minutes) or L/s
(Liters per Seconds) of fresh air being
distributed in the living space. The Room
Count Calculation or the Air Change per
Hour Method shows you how to
determine your ventilation needs.

Air Volume

Needed

installation

In a typical installation there must be an
adequate air volume passing through the
unit in proportion of the pressure from
the heating system.

Exemple: On the warm side*, the air vol-
ume needed is based on a 26’ rigid duct.
On the cold side*, the proportional eqiva-
lent is 18’ of rigid duct.

* Between the model SH and the

forced air system.

**Between the model SH and the

outside intake.

A. Room Count Calculation

B. Air Change per Hour Method

2. Typical Installation

1.Ventilation Needs

LIVING SPACE

Master Bedroom
With Basement
Without Basement
Single Bedroom
Living Room
Dinning Room
Family Room
Recreation Room
Other

Kitchen
Bathroom
Laundry Room
Utility Room

TOTAL cu ft X 0.3 per hr = total

Take total and divide by 60 to get CFM

Number of Rooms

CFM (L/s)

CFM Required

x 20 cfm (10 L/s)

=

x 20 cfm (10 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

x 10 cfm (5 L/s)

=

TOTAL ventilation requirement (add last column) =

25’ x 40’ house with basement
1,000 sq. ft. x 8’ high x 2
(1

st

floor = basement)= 16,000 cu. ft.

16,000 sq. ft. x 0.3 ACH = 4,800 cu. ft.
4,800 sq. ft. / 60 Minutes
= 80 CFM

1 CFM = 0.47189 L/s

1 L/s = 3.6 m

3

/hr

80 CFM is your ventilation needs

Example:

VENTILATION PERFORMANCE - MODEL SH

0.25

0.20

0.15

0.10

0.05

0.00

Supply

Return

60 70 80 90 100

Ft

3

/min. of HRV (Exhaust)

Supply

SUPPL

Y (“W

.C.)

0.25

0.20

0.15

0.10

0.05

0.00

60 70 80 90 100

Ft

3

/min. of HRV (Fresh Air Intake)

Return

RETURN (“W

.C.)