Worksheet, total combined power used by the server, Table 7, Power usage worksheet 2 – Intel SC5275-E User Manual

Page 62

Advertising
background image

Equipment Log and Worksheets

Intel® Entry Server Chassis SC5275-E User Guide

44

Worksheet, Total Combined Power Used by the Server

1. From the previous worksheet, enter the total current for each column.
2. Multiply the voltage by the total current to get the total wattage for each voltage level.
3. Add the total wattage for each voltage level to arrive at the total combined power usage for the

power subsystem.

Table 7.

Power Usage Worksheet 2

Voltage level and total current
(V X A = W)

Total Watts
for each voltage level

(+3.3 V) X (______ A)

________ W

(+5 V) X (______ A)

________ W

(

5 V) X (______ A)

________ W

(+12 V) X (______ A)

________ W

(–12 V) X (______ A)

________ W

(5 V standby) X (______ A)

________ W

Total Combined Wattage

________ W

CAUTION

Do not exceed a combined power output of 120 Watts for the +5 V and +3.3 V outputs. Exceeding
a combined 120 Watts will overload the power subsystem and

Advertising