Software Reset

Flash Program (Manufacturer only)

About (shows title screen followed by the software revision)

Features - Features list and activation code

Max. Angle Time

Use the

keys to scroll through the menu options

(displayed 1 per screen), and press

ENTER to edit.

Menu options are edited by using the

keys to scroll through

the options and then pressing

ENTER.

To exit without changing, press

ESCAPE.

To exit from any screen, press

ESCAPE.

POWER SETUP MENU

Use the Power Setup menu to change the following:

Battery Auto Off

(1, 2, 5, 10, 20, 30, 40 mins, 1 hour, 16 hours or Never Off)

Battery Backlight Off

(1, 2, 5, 10, 20, 30, 40 minutes, 1 hour, 16 hours, Never Off or Always

Off)

Note: The LCD is backlit to aid viewing in poor light conditions. The

backlight can be set to turn off after a certain time to conserve power.

When the backlight turns off, it will come back on by pressing any key.

Then the keys can be used for their normal functionality again.

Battery Type

Use only Ingersoll Rand battery pack ETW-EBP.

FEATURES
Activation Code

The Activation Code Feature is reserved for future use as a software

expansion tool.

Features List

This shows the features enabled on the Expert Torque Wrench.

The screen will only show 1 item at a time - scroll to reveal the rest.

Features which are enabled, are marked with a tick

.

Max. Angle Time

Allows the user to change the length of time the wrench will

continue taking a “slow” reading (i.e. an angle increase of less than

4 degrees per second).

Note: The slower an angle reading is taken, the greater its margin of

error. It is therefore recommended that this value be kept low unless

desired for Yield Control, where the acceptable range of angle error

is greater.

USING EXPERT TORQUE WRENCH WITH PC COMMS

First connect the Expert Torque Wrench to the PC with the

special cable - see page 7. From the Expert Torque Wrench Main

Menu, select the PC Comms option and enter the

Communications screen.

Open the PC Comms program on the PC and use the Test Link

function in the Communications menu to check the connection.

PC Comms will show ‘Link working’ if the connection is OK. If not,

check the correct comms port is selected in PC Comms and the

cable is connected correctly. When the link is established, use the

Download function to download a set of characteristics and User

IDs to the Expert Torque Wrench. For more information, please refer

to the PC Comms manual.

SOFTWARE RESET

To return the device to its factory settings, use the Software Reset

function.

Accessed via the Main Setup Menu page 11.

Screen will warn: ‘ATTENTION, ALL DATA AND SETTINGS WILL BE

LOST!’

Press

ENTER to reset or

ESCAPE to abort.

For service and repair, please ship to:

Ingersoll Rand

1872 Enterprise Drive

Rochester Hills, MI 48309