5.1 LSI* Add-in RAID Card Option ROM Utility Access Issue

Issue:

The system will hang when the BIOS assigns PMM segment 2FE00 and the user
tries to enter into the Ctrl-M RAID configuration utility.

Implication:

A user may be unable to access the option ROM utility (Ctrl-M) for the following
LSI adapters: MegaRAID* 320-2, MegaRAID 320-1, MegaRAID 320-0,
MegaRAID SATA 150-6, MegaRAID SATA 150-4 and older U160 SCSI
MegaRAID adapters.

Guideline:

BIOS P07.20 or later releases have corrected this issue, allowing users to
access the Option ROM utility for the above mentioned LSI add-in adapters.

Status:

LSI add-in MegaRAID 320-2, MegaRAID 320-1, MegaRAID 320-0, MegaRAID
SATA 150-6, MegaRAID SATA 150-4 and older U160 SCSI MegaRAID adapters
are only supported when using BIOS P07.20 or later releases.