Setup menu, Remote menu screen – JVC 240-020-505 User Manual

Page 42

Advertising
background image

70

Setup Menu

REMOTE MENU Screen

The following table identifies and describes the parameters that may be set using the REMOTE MENU screen.
Top half

: Appearance on monitor screen

Bottom half : Appearance on LCD display
[ ]

: Default setting

Parameter

Possible settings

Description

REMOTE SELECT

[OFF]

DV (SLAVE)

DV (TRIGGER)

REMoTE

[oFF]

dVS
dVT

REC CONTROL

[OFF]

ON

REC

[oFF]

oN

FOOT SW1

OFF

[LOW EDGE]

HIGH EDGE

LOW LEVEL

FSW1

oFF

[LE]

HE

LL

FOOT SW2

OFF

[LOW EDGE]

HIGH EDGE

BOTH EDGE

FSW2

oFF

[LE]

HE
bE

232C

[9600]

BAUDRATE

19200

Bps

[96]
192

This parameter is used to select a method for controlling external devices connected
via the DV IN/OUT terminal).
OFF

: Control is not to be carried out via the DV IN/OUT terminal.

This is the standard setting for normal operation.

DV (SLAVE)

: This DVD recorder will become the slave device and will be

controlled by the master device.

DV(TRIGGER) : This setting is made when this DVD recorder is connected to a DV

camera featuring a DV record triggering function, and it allows
this DVD recorder to record video from the camera in response to
operation of its trigger button.

This parameter is used to indicate whether or not the REC CONTROL panel is to be
displayed on the monitor screen.
ON

: The REC CONTROL panel is to be displayed only when a recordable disc

has been inserted and the DVD recorder is in Stop, Recording, or Recording
Pause mode.

OFF : The REC CONTROL panel not to be displayed.

Set this item when connecting an external switch (foot switch, etc.) to the FOOT
SW1 terminal.
OFF

: Set to this when an external switch is not used.

LOW EDGE : Switch between recording and record pause actions using the low

edge of external switch signals.

HIGH EDGE : Switch between recording and record pause actions using the high

edge of external switch signals.

LOW LEVEL : Use the low level and high level of external switch signals for recording

and record pause respectively.

Set this item when connecting an external switch (foot switch, etc.) to the FOOT
SW2 terminal.
OFF

: Set to this when an external switch is not used.

LOW EDGE : Add chapter marks and indexes using the low edge of external switch

signals.

HIGH EDGE : Add chapter marks and indexes using the high edge of external switch

signals.

BOTH EDGE : Add chapter marks and indexes using the low and high edges of

external switch signals.

For setting the communication speed of the RS-232C terminal.
9600

: Communicate at a rate of 9600 bps

19200 : Communicate at a rate of 19200 bps

71

Parameter

Possible settings

Description

232C

[TYPE1]

PROTOCOL TYPE

TYPE2
TYPE3
TYPE4
TYPE5
TYPE6
TYPE7
TYPE8

232C

[T1]

T2
T3
T4
T5
T6
T7
T8

MENU

MENU

Set this item according to the type of controller connected when performing remote
control using the RS-232C terminal.
TYPE1 : Standard operation mode
TYPE2 : For customized use
TYPE3 ~ TYPE8 : Spare

This button is used to return to the Setup Menu screen.