Jenn-Air GAS DOWNDRAFT COOKTOP PRO-STYLE User Manual

Page 4

Advertising
background image

S

AVE

T

HESE

I

NSTRUCTIONS

FOR

F

UTURE

R

EFERENCE

Jenn-Air’s ventilation system is designed
to capture both cooking fumes and smoke
from the cooktop surface. If the system
does not, these are some ducting
installation situations to check:

• 6" diameter round or 3

1

/

4

" x 10"

rectangular ducting should be used for
duct lengths 10'-60'. Note: 5" diameter
round ducting may be used if the
duct length is 10' or less.

• No more than three 90° elbows should

be used. Distance between elbows
should be at least 18".

the responsibility of the installer and
questions should be addressed first by the
installer. The installer should very carefully
check the ducting installation instructions.

• Use the Flow Tester Card provided with

your appliance to check the air flow.

D

UCTING

I

NFORMATION

• Recommended Jenn-Air wall cap MUST

be used. Make sure damper moves
freely when ventilation system is
operating.

• There should be a minimum clearance

of 4" for cooktop installed near a side
wall.

If there is not an obvious improper
installation, there may be a concealed
problem such as a pinched joint,
obstruction in the pipe, etc. Installation is

Advertising