Page 21

English

Troubleshooting Procedures

If the unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at 1-800-288-4002 with your bath’s serial number

before work is started. The serial number is located on the Specification/Serial Number Plate (see the following page).

PROBLEM

PROBABLE CAUSES

REMEDY

Contact Jacuzzi Luxury Bath @ 800-288-4002

Pump/motor does not start

Pump/motor shuts off by itself before time elapses

Chromatherapy lights do not operate

Pump/motor operates but no fully adjustable jets are

functioning

Water leakage from pump unions

No power to pump/motor

Pump/motor not plugged in

Pump/motor faulty

Motor thermal protection has deactivated pump/motor

due to overheating (supply voltage low)

GFCI tripped

Inadequate supply wiring

Reset GFCI

Insert plug securely into outlet

Ensure the control panel is conencted to control box

Contact Jacuzzi Luxury Bath @ 800-288-4002

Let motor cool; thermal protection will reset. Check for

proper ventilation (check supply voltage)

Reset GFCI. If it continues to trip, do not use this unit.

Disconnect the unit and have the problem corrected by

a licensed electrician before using.

Consult a licensed electrician to correct the wiring unit.

Connector has come loose

Jets are closed

Suction cover/strainer may be clogged

Open jets by rotating counter-clockwise

With the motor turned OFF, remove the suction cover/

strainer and remove any debris. Replace the suction

cover before operating

Overtightened, O-ring may be pinched or improperly

seated, undertightened

Loosen unions , check and reseat O-ring. If O-ring has

been pinched out of shape, replace (refer to number

below). When tightening union nuts, handtighten only.

Pump/motor operates but air is not injected into the

water

Air valves are closed

Open air control valves