Heat pump unit dimensions, Heat pump unit clearances – Johnson Controls R-410A User Manual

Page 76

Advertising
background image

333496-BTG-E-0610

76

Johnson Controls Unitary Products

Heat Pump Unit Dimensions

Note: For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch

between combustible roof curb material and this supply air duct.

Heat Pump Unit Dimensions

Unit Size

Dimensions

“A”

024, 030

1

, 036

1. BUZ and BUQ Models.

33-1/2

042

1

, 048, 060

41-1/2

Heat Pump Unit Clearances

Direction

Distance

(in.)

Direction

Distance

(in.)

Top

1

1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air

discharge outlet.

36

Right

24

Front

12

Left

24

Rear

0

Bottom

2

3

2. Units may be installed on combustable floors made from wood or class A, B or C roof covering

materials.

3. Minimum Clearance of 1inch all sides of supply air duct for the first 3 foot of duct for 20 & 25 kW., zero

inches there after. For all other heaters, zero inch clearance all sides for entire length of duct.

0

FRONT

(OVERALL)

(OVERALL)

(OVERALL)

COMPRESSOR SERVICE

ACCESS COMPARTMENT

PANEL

REFRIGERANT

CONNECTIONS

ELECTRICAL/FILTER

SERVICE ACCESS

COMPARTMENT PANEL

HIGH VOLTAGE CONN.

1-23/64" DIA. KNOCKOUT

UNIT CONDENSATE

CONNECTION 3/4" NPTF

(TRAP REQUIRED)

SIDE RETURN

AIR OPENING

SIDE SUPPLY

AIR OPENING

LOW VOLTAGE CONN.

7/8" DIA. KNOCKOUT

HIGH VOLTAGE CONN.

1-31/32" DIA. KNOCKOUT

HIGH VOLTAGE CONN.

7/8" DIA. KNOCKOUT

“A”

3-3/4

1-1/2

2-1/2

2-3/8

4-1/2

49-1/8

28-1/4

28-1/4

47-1/4

17-1/4

17-1/4

22-1/4

22-1/4