22

Setup

Connecting alarm input/output terminal

Alarm input terminal

Connect infrared sensor, door sensor, metal sensor or sensor of manual
switch and the like.

● To prevent noise from entering the internal circuit, supply non-voltage

setting signal.

● Do not supply voltage.

● Can be set via menu whether to set to alarm when the contact is short

(MAKE), or when the contact is open (BREAK). (

A Pg. 37)

● Supply such that the alarm signal continues for more than 200 ms. The

recognition of alarm signal may not be guaranteed if less than 200 ms.

Alarm output terminal

Connect to alarm devices such as alarm, indicator, light or buzzer.

● As it is an open type collector output insulated by photocoupler, it will turn

on during alarm.

● This terminal has polarity. Make sure to connect such as the voltage of +

terminal is higher than - terminal. It will be damaged if reverse voltage is
supplied.

Connecting the back panel (continued)