19

Programming options

Objective

Implementation

Permanently programme on the audi-
ble signal which reminds you that the
programme is complete.

1. Turn the programme selector to any programme.
2. Press the ALARM button and hold down for approx. 5 seconds.

A brief signal sounds several times. The ALARM display flashes several times.
The setting is permanently programmed.

The setting is cancelled as described under 1 and 2.

Adjust “level of dryness” detection:
If you wish the laundry to be slightly
drier or slightly damper at the end of
the programme than with the stand-
ard setting.

1. Turn the programme selector to any programme.
2. Press the SILK and ALARM buttons at the same time and hold down for approx. 5

seconds.
The current setting appears on the multi-display:
– C0: Setting for drier laundry
– C1: Standard setting
– C2: Setting for damper laundry

3. Press the START/PAUSE button until the setting required appears on the multi-dis-

play.

4. Turn the programme selector to OFF.

The setting is permanently programmed.

To deactivate the FULL TANK display
when using an external drain for the
condensed water.

1. Turn the programme selector to any programme.
2. Press the WOOL and ANTI-CREASE buttons at the same time and hold down for

approx. 5 seconds. The multi-display briefly displays ”0”
The FULL TANK display is permanently deactivated.

The setting is cancelled as described under 1 and 2; the multi-display however briefly
displays ”1” (rather than ”0”).