No. 52025

AV-20N3

AV-20NMG3

AV-20NMG3B

24

Item

Measuring

instrument

Test point

Ad justment part

Description

5. COLOUR

[Method of adjustment using measuring instrument]

PAL COLOUR

1. Input a PAL full field colour bar signal (75% white).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 5. COLOUR with the MENU ▼/▲ key.
5. Set the initial setting value of PAL COLOUR with the MENU

- / + key.

6. Connect the osc illosc ope between TP-47G and TP-E (#).
7. Adjust PAL COLOUR to bring the value of

(A)

in the illustration

to the voltage as shown given billow.
(Voltage differenc e between (W) and (G))

SECAM COLOUR

1. Input a SECAM full field colour bar signal (75% white).
2. Set the initial setting value of SECAM COLOUR with the MENU

- or + key.

3. Adjust SECAM COLOUR to bring the value of

(A)

in the

illustration to the voltage as shown given billow.

(Voltage differenc e between (W) and (G))

NTSC 3.58 COLOUR

1. Input a NTSC 3.58 full field colour bar signal (75% white).
2. Set the initial s etting value of NTSC 3.58 COLOUR with the

MENU - / + key.

3. Adjust NTSC 3.58 COLOUR to bring the value of

(A)

in the

illustration to the voltage as shown given billow.

(Voltage differenc e between (W) and (G))

Ad justment
of SUB
COLOUR

Signal
generator

Oscillo-
scope

Remote
control unit

TP-47G/R

TP-E (#

#

#

#

)

[CRT SOCKET
PWB]

NTSC 4.43 COLOUR

When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the
respective values .

W

Y

Cy

G

Mg

R

B

(A)

0V

(-)

(+)

Model

Voltage(W-G)

AV-20N3
AV-20N3

/D

+14V

AV-20NMG3
AV-20NMG3B
AV-20NMG3

/-A

+10V

Model

Voltage(W-G)

AV-20N3
AV-20N3

/D

+11V

AV-20NMG3
AV-20NMG3B
AV-20NMG3

/-A

+10V

Model

Voltage(W-G)

AV-20N3
AV-20N3

/D

+8V

AV-20NMG3
AV-20NMGB
AV-20NMG3

/-A

+10V