background image

No. 52025

AV-20N3

AV-20NMG3

AV-20NMG3B

28

Item

Measuring
instrument

Test point

Ad justment part

Description

When the vertical linearity has been deteriorated

remarkably, perform the following steps.

15. Input a cross -hatch signal.
16. Select 4. VER. LIN. with the MENU ▼/▲ key.
17. Set the initial s etting value of 4. VER LIN. with the MENU - / +

key.

18. Select 5. VER. SCURVE with the MENU ▼/▲ key.
19. Set the initial setting value of 5. VER. SCURVE with the MENU

- / + key.

20. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces

of each line as shown in Fig.3 on TOP, CENTER and
BOTTOM become uniform.

Ad justment
of VER. LIN.
& VER.
SCURVE

Signal
generator

Remote
control unit

4. VER. L IN.
5. VER. SCURVE

Make sure that the adjustment is properly done on the screen of
60Hz mode.
[NOTE]

"

Adjust to make both 50Hz & 60Hz are the same v. size and

fine straight line.

"

When adjust again, adjust 50Hz mode first.

"

When adjust in 60Hz mode, only 60Hz mode is adjust.

VSM PRESET SETTING

Item

Measuring

instrument

Test point

Ad justment part

Description

Setting of
VSM
PRESET

Remote
control unit

TINT
COLOUR
BRIGHT
CONT .
SHARP

1. Enter the SERVICE MENU.
2. Select 4. VSM PRESET from the SERVICE MENU.
3. Select BRIGHT with the PICTURE MODE key.
4. Adjust the MENU ▼/▲ and MENU - / + key to bring the set

values of TINT

SHARP to the values shown in the below

table.

5. Respectively s elect the VSM PRESET mode for SOFT and

STANDARD, and make s imilar adjustment as in 3 above.

TOP

CEN TER

BOTTOM

Fig.3

BRIGHT

TINT

COLOUR
BRIGHT

CONT.
SHARP

- / + : OPERATE DISP : EXIT

**
**
**
**
**

/ :SELECT

••••

VSM PRESET

VSM
Setting Item

BRIGHT

STANDARD

SOFT

TINT

+15

COLOUR

+15

BRIGHT

+15

CONT

+30

+15

+11

SHARP

+15

+12

Advertising