STATIC CONVERGENCE ADJUSTMENT

1. Input a cross hatch signal.

2. Using 4-pole convergence magnets , overlap the red and blue

lines in the center of the screen (Fig.1) and turn them to
magenta (red/blue).

3.

Using 6-pole convergence magnets, overlap the
magenta(red/blue) and green lines in the center of the screen
and turn them to white.

4. Repeat 2 and 3 above, and make best c onvergence.

DYNAMIC CONVERGENCE ADJUSTMENT

1. Move the deflec tion yok e up and down and overlap the lines in

the periphery. (Fig. 2)

2. Move the deflection yoke left to right and overlap the lines in the

periphery. (Fig. 3)

3. Repeat 1 and 2 above, and make best c onvergence.

After adjustment, fix the wedge at the original position.

Fasten the retainer screw of the deflection yoke.
Fix the 6 magnets with glue.

(FRONT VIEW )

GREEN

(FRONT VIEW )

BLUE

RED

BLUE

GREEN

RED

RED

GREEN

BLUE

GREEN

RED

BLUE

GREEN

(FRONT VIEW )

BLUE

RED

BLUE

GREEN

RED

RED
GREEN

BLUE

GREEN

RED

BLUE

Fig.3

Fig.2

Fig.1