Abnormal led activity, Abnormal led activity -8, Table 8-3 – Juniper Networks ERX-1410 User Manual

Page 114: Table 8-4, See table 8-4 to diagnose and correct problems

Advertising
background image

CHAPTER 8
Troubleshooting

8-8

If the system detects an error during booting, the FAIL LED turns on.
Some failure conditions may cause the board not to boot. In this case, the
LEDs may all be off. The system should then reset the board.

If the operational software detects an error, the FAIL LED turns on.
Some errors may cause a board reset. Crash information can be displayed
from the console and is printed to the screen on the next reboot.

Abnormal LED Activity

See

Table 8-4

to diagnose and correct problems.

Table 8-3 Normal activity of functional status LEDS during booting

OK

FAIL

ONLINE

Status Process

off

on

off

1 Module is in the power-up restart state; the FAIL

LED stays on briefly.

off

off

off

2 Module is initializing, and diagnostic tests are

running.

on

off

off

3 Module passed the diagnostics; the system boots.

on

off

on

4 Module is now up and running.

Table 8-4 Troubleshooting abnormal LED activity on modules

Diagnostic Signs

Possible Problems

Actions

POWER A OK is not lit

POWER B OK is not lit

System is not receiving
power from Power A.

System is not receiving
power from Power B.

1 Check Power A and Power B terminal connections.
2 Verify that power switches are on.
3 Check connections to power sources.
4 If system still does not operate, contact Juniper

Networks Customer Service.

FAIL LED lights

The line module and I/O
module are incompatible.

A hardware failure, such
as a failed module.

1 Check that the line and I/O modules are compatible;

replace if necessary.

2 If you replaced the I/O module only, issue the reload

slot slot_number command.

3 If you replaced the line module or if there was a

hardware failure, the system should automatically
reset the module.

4 If condition persists, contact Juniper Networks

Customer Service.

FAN OK does not light

FAN FAIL LED lights

Fan is not working
properly or has slowed
down.

Fan needs replacement.

Contact Juniper Networks Customer Service; the system
must be serviced.