Removing sfps, Removing sfps -6 – Juniper Networks ERX-1410 User Manual

Page 98

Advertising
background image

CHAPTER 7
Maintaining the ERX System

7-6

Removing SFPs

To remove the SFPs:

1

Obtain an antistatic container for the SFPs you will remove (see

Storing Modules and Components

, earlier in this chapter).

2

Put the antistatic wrist strap on your wrist, and connect the strap to
the ESD grounding jack on the system.

3

Disconnect the cables from one of the SFPs on the module.

4

Identify the release mechanism for the SFP.

Different SFPs use different release mechanisms (see

Figure 7-2

).

Possible release mechanisms include:

A button that you press inward

A ring that you press inward

A bar that you pull sideways, then outward

A tab that you pull sideways, then outward

Figure 7-2 Possible release mechanisms on the SFP

5

Release the SFP and pull it out of the slot.

6

Place the SFP in an antistatic bag.

7

If you are using the redundant port on the ERX GE

I/O module,

repeat steps

3

through

6

for the other SFP.

Caution: For port redundancy to operate correctly, both the primary and redundant
ports on an ERX GE I/O module must use the same type of SFP.

Release bar, button,

or tab

Release ring

Transceiver

Release bar, button,

or tab

Module faceplate

Advertising