Electrical connection

Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.

WARNING: THIS APPLIANCE MUST BE
EARTHED.

The manufacturer declines any liability

should this safety measure not be
observed.

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance’s
rating plate. The rating plate is located at the top of the
rim of the open door.

The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1363/A) fuse
must be used.
Should the plug need to be replaced for any reason,
proceed as described below.

Mod. ..........

Prod. No. ...........

Ser. No. .........

M

od. ..........

Pro

d. N

o. ...........

Se

r. N

o. .........

P0042 BD

SHOWER

BATH

SINK TOILET

BIDET

WASHING

MACHINE

DISHWASHER

RAINWATER

'RUN-OFF'

SURFACE WATER

DRAINS & SEWERS

UNTREATED

DISCHARGE

RIVER

FOUL DRAIN

FOUL SEWERS

SEWAGE

TREATMENT

WORKS

RIVER

P0987

TREATED

DISCHARGE

The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

The wire coloured green and yellow must be
connected to the terminal marked with the letter «E»
or by the earth symbol

or coloured green and

yellow.

The wire coloured blue must be connected to the
terminal marked «N» or coloured black.

The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of
safely.

The power supply cable must be easily
accessible after installing the appliance.

Important

If the mains supply cable is damaged it must be
replaced; contact our warranty administrators on
0870 0107887 who will give you details for your local
Service Force Centre.

Permanent connection

In the case of permanent connection it is necessary
that you install a double pole switch between the
appliance and the electricity supply (mains), with a
minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance
with the current electrical regulations.

The switch must not break the yellow and green earth
cable at any point.

GREEN & YELLOW

BROWN

CORD CLAMP

BLUE

13

A

P1041

E

N

L