Alc level av pk lh – JVC TK-C1530U User Manual

Page 9

Advertising
background image

16

Introduction

Q

[RX TERM-OFF,ON/INT,LL] Function Selector Switch

[RX TERM-OFF,ON] RX Signal Terminal ON/OFF Switch
This sets whether or not the signal between RX+

and RX-

from the

control signal connection terminals

L should be terminated at the value of

110

K resistance.

ON

: Terminated at 110

K.

OFF

: Not terminated at 110

K.

If the system including the camera is the MULTIDROP (Multi DROP, RS-485)
system, only the last camera mounted along the control signal cable is set to

AONB and the other cameras are set to AOFFB. (In the case of the
MULTIDROP system, it is necessary to set the MACHINE ID.)
If the system including the camera is the P TO P (Point to Point, RS-422A)
system, set this switch of all the cameras to

AONB. To switch between

communication systems, use the item STYLE on the COMMUNICATION
screen. (

A Pg. 51)

(Default setting: ON)
[NT,LL] Selector Switch for Synchronizing System
This switch sets the synchronizing system for the camera.
INT

: This is set for internal synchronization (INT).

LL (Line Lock)

: This is set to synchronize the camera’s vertical

synchronization to the power frequency.
(Default setting: INT)

R

[POWER] Power indicator lamp

This lamp lights up when power is supplied to the camera.

S

Mounting Screw for Fall Prevention Wire

Use this screw when mounting the fall prevention wire to this unit. (Fall
prevention wire is not supplied with this product.)

Note:

● Connect the fall prevention wire to prevent this unit from falling accidentally.

T

AC 220 V

-240 V power cord

This connects the camera to a commercial AC 220 V

-240 V socket.

Name of Parts and their Functions (continued)

C

D

: Only for TK-C1530U/E and TK-C1531EG

17

Setup

Memo:

● Turn off the power of devices to be used before connecting the cables.

● Read through the “Instruction Manual” of the devices to be used carefully

before connecting.

● For the types of connecting cables and the distances required, read

AConnecting the back panelB (A Pg. 22) carefully before connecting.

● Loop connection cannot be made for control signal cables.

System Example

1

TO CAMERA

DATA I / O

RX+ RX- TX+ TX-

COM

1

2

3

4

5

6

7

8 COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8 COM

COM

COM

CAMERA

SW

UNIT

ALARM

AUTO

4

3

1 2

8

7

5 6

2

3

4

5

6

7

8

1

MONITOR

OUTPUT

MONITOR

SERIAL-2

SERIAL-1

VIDEO INPUT

VIDEO OUTPUT

OUTPUT

2

1

ON

2

3

4

5

6

7

8

DIGITAL

ALC

LEVEL

Av

Pk

LH

DIGITAL

ALC

LEVEL

Av

Pk

LH

DIGITAL

ALC

LEVEL

Av

Pk

LH

Camera 1

Camera 2

Camera 8

Control Signal

Cable

Power
Cable

TK-C1530U/E : AC24 V or DC12 V
TK-C1531EG : AC220 V

-240V

Video Signal Cable

Remote control unit and etc

Monitor

MACHINE ID : 1
(MENU screen)
RX TERM : OFF
(Switch)

MACHINE ID : 2
(MENU screen)
RX TERM : OFF
(Switch)

MACHINE ID : 8
(MENU screen)
RX TERM : ON
(Switch)

: Only for TK-C1530U/E and TK-C1531EG