Vent windows for natural gas, Ba c, Colinear vent coaxial vent – Jotul GF300 DV User Manual

Page 10

Advertising
background image

10

HORIZONTAL RUN

35 Ft.

(10.67 m)

30 Ft.

(9.14 m)

25 Ft.

(7.62 m)

20 Ft.

(6.10 m)

15 Ft.

(4.57 m)

5 Ft.

(1.52 m)

10 Ft.

(3.05 m)

5 Ft.

(1.52 m)

VERTICAL

RUN

15 Ft.

(4.57 m)

20 Ft.

(6.09 m)

27 Ft.

(8.22m)

12 Ft.

(3.65 m)

8 Ft.

(2.43 m)

A

D

Min. Rise

2 Ft.

(.60 m)

Up to four 45° or

two 90° elbows

permitted in

addition to the

starter elbow.

B

B

A

C

Min. Vertical

Termination

Figure 9. Coaxial Vent Termination Window / NG

Figure 10 . Colinear Termination / NG

• ALL VENTING MUST TERMINATE (END) WITHIN ONE OF

THE SHADED AREAS.

• SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT

CORRESPONDS TO THE VENT TERMINATION AREA IN THE

DIAGRAM ABOVE.

• ALWAYS MAINTAIN THE PROPER CLEARANCES TO

COMBUSTIBLES.

The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installation
and fuel type, then adjust the restrictor to the corresponding
position as shown in figure 7, page 9.

Vent Windows for Natural Gas

COLINEAR VENT

COAXIAL VENT

• VENTING MUST TERMI-

NATE (END) WITHIN THE

SHADED AREA.

• Adjust the Exhaust

Restrictor to position B
for any NG colinear
termination.

• Max. Offset: 2 ft. (610

mm)

HORIZONTAL RUN

35 Ft.

(10.67 m)

25 Ft.

(7.62 m)

2 Ft.

(16 cm)

VERTICAL

RUN

Minimum

Vertical

Termination

8 Ft.

(2.43 m)

35 Ft.

(10.67 m)

25 Ft.

(7.62 m)

2 Ft.

(16 cm)

VERTICAL

RUN

Minimum

Vertical

Termination

8 Ft.

(2.43 m)

45°

Elbow

Up

B